analysis SectionΒΆ

This section configures harmonic analysis settings in T-UGOm, including tidal spectrum, admittance methods, and spectral solver configurations.


Parameter

Description

OnOffFlag

Flag to enable/disable harmonic analysis (TRUE, FALSE).

list_file

File containing the list of tidal waves for analysis.

auto_completion

Flag to enable/disable auto-completion of tidal spectrum (TRUE, FALSE).

harmonic_start

Time after which analysis starts (default: 2*#MODEL.$spinup./3600/24.0, in days).

sample_interval

Sampling interval for analysis (default: 1800 s).

compute_interval

Interval for computing harmonic analysis (default: 365 days).

rayleigh_factor

Rayleigh criterion threshold (default: 0.5, dimensionless).

admittance_method

Method for admittance (NONE, LINEAR, SPLINE).

strategy

Strategy for harmonic analysis (FULL, REINITIALISE, SEQUENTIAL).

sequential_recycle

Flag to recycle sequential solutions (MANAGED, FALSE, TRUE).

sequential_archive_level

Archive level for sequential solutions (MINIMAL, STANDARD).

LGP1ArchiveFlag

Flag to create a LGP1xLGP1 ASCII archive (TRUE, FALSE).

ASCIIArchiveFlag

Flag to create an ASCII UG archive (TRUE, FALSE).

NETCDFArchiveFlag

Flag to create a NetCDF UG archive (TRUE, FALSE).

zone

Definition of structured grid (AUTO, FILE, SYMPHO).

SGFlag

Flag to enable/disable structured grid archive (TRUE, FALSE).

surface_elevation

Flag to include surface elevation in analysis (TRUE, FALSE).

horizontal_currents

Flag to include horizontal currents in analysis (TRUE, FALSE).

LSA_potential

Flag to include LSA potential in analysis (TRUE, FALSE).